Language / 语言
Vendor Specification
DOCX PDF
Product Modification Specification

FLIX RS-485

Professional RS-485 / Crestron compatible keypad frame. Two variants: 3-Element Frame and 4-Element Frame. Replaces AC power module and Wi-Fi with clean 24V DC wired control.

2RS-485 Devices / Frame
4Buttons per Keypad Element
24V DCExternal Power (no AC module)
Modbus RTUCommunication Protocol
9600Baud Rate (default)
01 — Product Overview

Frame Layout & Element Structure

The FLIX RS-485 product comes in two frame variants. Each frame fits into a standard Indian electrical backbox. The frame has smart keypad elements on the left and right, and physical socket elements in the center.

Select Frame Variant to Preview
Element Summary
PositionElementTypeDescription
02 — Design Changes

Current Design vs New RS-485 Design

The consumer FLIX uses Wi-Fi/Zigbee and an AC power module. The RS-485 professional version removes both and replaces them with a clean wired RS-485 interface.

03 — Addressing

Two RS-485 Devices per Frame

Both the 3-element and 4-element frame have exactly 2 RS-485 devices inside — the LEFT keypad and the RIGHT keypad. Center socket elements have no RS-485 connection.

Interactive DIP Switch Address Calculator
Click the switches to set address — see result instantly
RS-485 Address
1
Binary
00000001
Address Convention Example
FrameElement AddressControls
04 — PCB Hardware

PCB Modifications — Per Keypad Element

These changes apply to each 4-button keypad PCB. Both LEFT and RIGHT keypads need identical modifications. Same PCB design works for 3-element and 4-element frame.

Components to ADD
Components to REMOVE
Remove ThisReason
05 — Connector

4-Pin Screw Terminal Specification

Each keypad PCB has one 4-pin screw terminal on the back. All RS-485 data and 24V power go through this single connector.

Terminal Specifications
06 — Electrical

Electrical Specifications

Power and signal requirements for the RS-485 keypad elements.

Power Requirements
RS-485 Signal Specifications
ParameterValue
07 — Protocol

Communication Protocol — Modbus RTU

Both keypad elements use Modbus RTU over RS-485. The Crestron processor is the Master. Each FLIX keypad is a Slave with its own address.

Serial Port Settings
08 — Register Map

Modbus Register Map

Click any register row to expand details. Applies to both LEFT and RIGHT keypad elements independently at their own addresses.

Write Registers — Crestron → Keypad (Control LEDs)
Read Registers — Keypad → Crestron (Button Events)
09 — Firmware

Firmware Requirements

For the firmware engineer. Same firmware code for LEFT and RIGHT keypad PCBs. Same firmware for 3-element and 4-element frame. Only DIP switch address differs.

10 — Wiring Guide

Step-by-Step Wiring Guide

Follow these steps in order to correctly wire the FLIX RS-485 frame.

Cable Specification
PropertySpecification
11 — Testing

Testing Requirements

Complete all tests before mass production. Click each test to mark as done and track progress.

0 / 8 completed
0% complete